Bitumen & road construction

Gear pump for Cut-back bitumen

Cut-back is bitumen fluxed with solvents such as kerosene or naphtha: easier to pump than straight bitumen and handled at lower temperature, but with volatile, flammable fractions. In classified areas we evaluate the pump with ATEX documentation, and seals and gaskets are chosen for the solvent, not only for the heat.

Request a quote for Cut-back bitumen

What makes Cut-back bitumen difficult to pump

Solid or semi-solid when cold

It must be heated before start-up and kept at temperature through the whole pumping chamber, seal area included.

High viscosity that changes with temperature

The pump is sized at the coldest working temperature and turns slowly, so the gear teeth fill completely.

Flammable or volatile

In classified areas the pump is evaluated with ATEX documentation, and seals are chosen for the light fractions.

How we build the pump for Cut-back bitumen

Recommended seriesCR · SB
Flow range of these series15 – 4,292 l/min (0.87 – 258 m³/h)
Body materialCast iron as standard; stainless steel NAV for aggressive variants
HeatingRequired — CR jacket on thermal oil, steam or superheated water; hot-spot kit without boiler; or electric cartridges in the body
SpeedLow speed: a larger pump turning slowly, often with a gear motor or inverter
Shaft sealsSelected for compatibility with the solvent or hydrocarbon
Classified areasPump evaluated with ATEX documentation
ConnectionsSB: flanged onto the tank

Where Cut-back bitumen pumps work

Applications: Prime coat and tack coat sprayers, surface dressing, rural road programmes, maintenance crews.

Typical markets: Nigeria, Ghana, Kenya, Tanzania, Ethiopia, Zambia, Pakistan, Bangladesh, Iraq, Yemen. For these sites we size for local conditions: the coldest night temperature, 50 or 60 Hz power, heating available on site and spare parts that can be kept in stock locally.

Recommended pump series

Data we need to size your Cut-back bitumen pump

  • Product name, producer or data sheet of the Cut-back bitumen
  • Viscosity at the pumping temperature, and the lowest temperature on site
  • Flow rate required (l/min, m³/h or bbl/h)
  • Discharge pressure, or line length, diameter and height
  • Suction: tank, line length and diameter, liquid level
  • Heating available on site: steam, thermal oil, hot water or electricity only
  • Power supply: voltage and 50 or 60 Hz; area classification

Frequently asked questions

Which gear pump do you recommend for Cut-back bitumen?

We normally propose the CR or SB Series. The CR is heating jacket wrapped around the whole pumping chamber. The final model depends on flow, viscosity at temperature and suction, and is confirmed by our technical office.

Does a pump for Cut-back bitumen need heating?

Yes. Without heat the product sets in the chamber and the pump cannot start. We use the CR jacket on the plant heating circuit, the hot-spot kit where there is no boiler, or electric cartridges in the body.

Can the pump work in an ATEX zone?

For classified areas we evaluate the pump with ATEX documentation. Tell us the zone classification in your request.

Do you supply pumps outside Italy?

Yes. The pumps are built in our Bologna workshop and quoted for export. Write your country in the form and we will size the pump for your power supply (50 or 60 Hz) and site conditions.

This page also covers: Cutback, MC-30 / MC-70 / RC grades.

Related fluids

All bitumen & road construction fluids →

Request a quote

Request a quote for a Cut-back bitumen pump

Send fluid, temperature and flow. Our technical office in Bologna replies by email with the pump model and a quote.

  • Answer in English
  • No obligation
  • Pumps built in Bologna, Italy

Our technical office in Bologna answers in English. No obligation.

Request a quote